Mettler Toledo MT Operations Instructions Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
Dispensing functions
Operating instructions 22012836B 09/08 11
IND690-Fill
1.9 Redispensing
If, for example, the weight value is briefly exceeded, the fine feed is switched off too
early and the current weight value (actual value) is below the target value.
During redispensing the fine feed is opened in intervals until the target value is
reached. Depending on the setting in the master mode, redispensing is carried out
manually or automatically, see section
2.2.
Manual redispensing
Prerequisite
MANUAL REDISPENSING is set in the master mode.
When the display shows MANUAL, press and hold down the MAN key.
The fine feed is switched on in pulses as long as the key is pressed and until the
target value is reached.
1.10 Manual recorrection
If MANUAL CORRECTION ON is set in the master mode, the display shows MANUAL
CORRECTION after the actual-target comparison if the final weight lies outside the
tolerances.
Recorrect manually and confirm correction with START key.