44 Operating instructions 22012836B 09/08
IND690-Fill
6.2 Sequence chart
6.2.1 Below-level application
NOZZLE CONTROL OFF and DRIP PAN OFF
OUT1 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 IN1 IN2 IN4
Fine feed Coarse
feed
Poor Accept-
able
End of
dispens-
ing
Start/
output 7
Ready Nozzle Start
(PLC)
Confirm
Target value entered
Pulse output started, nozzle
moves down, sequence
monitoring active
Nozzle down, PLC outputs start
pulse, coarse feed switched on
Limit 1 reached: coarse feed
switched off, fine feed switched on
Limit 2 reached: fine feed
switched off, nozzle moves up
Nozzle up, wait for stabilization of
weighing platform
Stabilization of weighing platform,
feed result evaluated and printed
out
Movement > 30 or confirmation
Ready for next dispensing