Chapter 4: Setup Parameters and Calibration
4-3 (08/09)
Configuring Setup
Parameters
WARNING
ONLY PERMIT QUALIFIED PERSONNEL TO SERVICE
THIS EQUIPMENT. EXERCISE CARE WHEN MAKING
CHECKS, TESTS AND ADJUSTMENTS THAT MUST BE
MADE WITH POWER ON. FAILING TO OBSERVE
THESE PRECAUTIONS CAN RESULT IN BODILY HARM.
To enter the setup mode, press and hold the UNITS key for up to eight seconds
until the message Setup is displayed. Release the UNITS key, and the first function (PB
0) will be displayed.
To program the scale, use the two function keys as follows:
Units Key - will accept the current displayed parameter value and increment to the
next function (IE: program block or Step).
Zero Key - will scroll through the available parameters for a specified function,
(IE: program block or Step).
This section describes the program blocks that govern normal operation including:
Pb 0 Push Button Zero Range*
PAr Parity –RS232
0 CurS Zero Cursor (indicator bar) * StoP Stop Bits – RS232
unitS Units displayed at Power-up * Proto Comm. Protocol –RS232
buiLd Build (Capacity/Increment)* SLEEP Sleep
ALt Alternate Units (Switching) Geo in GeoCal™ *
nodE Mode * CAL V Cal Weight used*
FiLtEr Filter CAL Calibration *
bAud Baud Rate – RS232 End End
ASCii
ASCII – RS232
* Items are locked by the Calibration Jumper W1
The PS scale can also be configured remotely through the METTLER TOLEDO Host
Interface. Details for configuring the scale using the Host Interface are given in the
Appendix at the end of this manual.
Program Menu chart
Units Key - will accept the value
and scroll vertically to the next step.
Zero key - will move horizontally to
the next parameter value.
To exit the set up program early:
First Method
o Press the UNITS key repeatedly
until End is displayed.
o Press the ZERO key until SAVE
or Abort is shown.
o Press the UNITS key to accept
Second method
Disconnect the power from the
scale. Changes will not be saved.
The 7 segment display is limited on
the Alpha characters that can be
displayed, (IE: no “m” can be
displayed so letter “n” is used
instead.