METTLER TOLEDO PS Shipping Scale: Technical Manual
4-6 (08/09)
Power-
up units
Model Option Display Range
Unit
Switch
Capacity and Resolution
Metric
(kg)
PS15
1 15-005 S Yes 15 x 0.005 kg
2 15-002 S Yes 15 x 0.002 kg
3 15-ni MI No 0-3 x 0.001 / 3-15 x 0.005 kg,
4 15-nC S No 15 x 0.005 kg
PS30
PS3L
1 30-02 S Yes 30 x 0.02 kg
2 30-01 S No 30 x 0.01 kg
3 30-ni MI No 0-15 x 0.005kg / 15-30 x 0.01 kg
PS60
PS6L
1 60-01 S Yes 60 x 0.01 kg
2 60-02 S Yes 60 x 0.02 kg
3 45-05 S Yes 45 x 0.05 kg
4 45-02 S Yes 45 x 0.02 kg
5 60-ni MI No 0-30 x 0.01kg / 30-60 x 0.02 kg
6 70-ni MI No 0-50 x 0.02kg / 50-70 x 0.05 kg
7 60-nC S No 60 x 0.02 kg,
8 45-ni S Yes 0-45 x 0.05kg
PS90
1 60-02 S Yes 60 x 0.02 kg
2 100-05 S Yes 100 x 0.05 kg
3 150-05 S Yes 150 x 0.05 kg
4 150-nC S No 150 x 0.05 kg,
5 60-05 S Yes 60 x 0.05 kg
6 90-1 S Yes 90 x 0.01 kg
o Range: S = Single Range, MR = Multi-Range, and MI = Multi-Interval with the
auto ranging ability.
o Unit Switch: Yes means that unit switching is permitted and can be set in the
Alt program block below. No means unit switching is inhibited. Resolution
and increment size of the alternate units will be the same option number for
that PS scale model. PS60 in pounds with option 5 of 100-05 build will have
the capacity of 45 kg and 0.02 kg resolution when switching to metric units.
3. Press UNITS to accept the displayed option. The PS continues to the Alternate Units
program block.
Note: the scale can only be sealed for Weights and Measure in the build that is listed on
the data label. The PS6L and PS60 have the same listing on the display for the
selection of the capacity and increment size, but utilize different load cells.
Alternate Units
This program block lets you enable or disable unit switching during normal operation.
Unit switching must be permitted in the buiLd selection above.
To configure the program block:
1. Press UNITS to display the ALt prompt, then press ZERO.
2. Press ZERO to display the desired approval setting, enable or disable.
3. Press UNITS to accept the displayed option. The PS continues to the Mode / Filter
program block.
Note: Resolution and
increment size of the
alternate units will be
the same option
number for that PS
scale model.